Can annealed glass be used in shop fronts?

Laminated safety glass is commonly used in shop fronts. However, Approved Document K (England) permits thick annealed glass to be used in such applications. Panes forming parts of fronts (but not other locations) to shops, showrooms, offices, factories and public buildings, supported on all edges, may be of equivalent robustness not complying with BS EN 12600, as follows:
  • 8 mm must not exceed 1100 x 1100 mm
  • 10 mm must not exceed 2250 x 2250 mm
  • 12 mm must not exceed 4500 x 4500 mm
  • 15 mm (and thicker) – no limit
Was this helpful?
Yes
No
Thank you for your feedback.
We're sorry to hear that, please refine your search and try again.

We value your privacy.

We use cookies on this website for analytics, remarketing, social media (optional) and content (essential) purposes.

By clicking ‘Accept All’ you consent to the use of cookies for non-essential functions and the related processing of personal data. Alternatively you can reject non-essential cookies by clicking ‘Essential Only’. You can adjust your preferences at any time by visiting our Cookie Policy and access the settings on that page.