TRIPLE GLAZED INSULATING UNITS
Triple Glazed Insulating Units can be incorporated into the Pilkington Planar™ System to give better thermal insulation:
- Generally they comprise of:
- an outer pane of 10,12, 15 or 19 mm thick glass
- each of the two airspace widths is 16 mm the optimum for thermal insulation
- inner panes of 6mm thick glass
- Low emissivity Pilkington K Glass™, Pilkington Planar™ Suncoated High Performance and Argon filling can also be used to increase thermal performance
- A discrete injection moulded boss is used to enable the bolt to pass through the three panes of glass and the airspaces and fasten back to the structure